Test Code DBIL Bilirubin, Direct
Additional Codes
Test ID |
DBIL |
EPIC Test ID |
LAB52 |
Performing Laboratory
St. Luke's Hospital Cedar Rapids
Specimen Requirements
Container/Tube:
Preferred: Green-top (lithium heparin) tube
Acceptable: Gold-top serum gel tube, plain red-top tube
Specimen Volume: 0.1 mL of plasma or serum
Stability: Samples can be kept at 20-25°C for 2 days. 2 – 8°C for 7 days. For longer storage, samples may be frozen at -20°C for up to 6 months.
Transport: Refrigerated
Collection Instructions: Bilirubin is photosensitive. Specimen must be protected from light. Primary tubes acceptable if the test label covers the majority of the tube for transport. If aliquoted, place in amber vial or protect from light.
Reference Values
0.0-0.3 mg/dL
Day(s) Test Set Up
Monday through Sunday
Useful For
Measurements of bilirubin are used in the diagnosis of liver disease, in the detection of hemolytic anemia, and to evaluate degrees of jaundice.
Methodology
Jendrassik-Grof End point with Sample Blank
Test Classification and CPT Coding
82248
Report Available
STAT within one hour of receipt.
Routine within 2 hours of receipt.