Sign in →

Test Code DONMER HLA Donor Specific Antibody (DSA) [Transplant]

Additional Codes

 Test ID

DONMER

EPIC Test ID

LAB4019

 

Specimen Requirements

Container/Tube Type: 

This test requires it's OWN collection tube.
Send specimen in original container.

Preferred Collection Container: 

SST (Serum Separator)

Also Acceptable Collection Container: 

Red (No Additive)
Lavender (EDTA)

Collection Information: 

Collect 6.0 mL of whole blood into a serum separator tube (preferred). This test requires it's own collection tube and the specimen should be submitted in the original container. NOTE: tube can be shared with other HLA testing.

Transport Information: 

Allow tube to clot for 30 minutes and then centrifuge and refrigerate. Specimens may be received unspun if collected in red top or lavender tube. Send original tube.

Minimum Sample Volume

3.0 mL

Specimen Stability

Refrigerated Stability: 

14 days - Preferred

Frozen Stability: 

NOT Acceptable

Ambient Stability: 

7 days

Report Availibility

Performed: 

Monthly and on STAT request

Analytical Time: 

30-60 days or 24 hours for STAT

Unacceptable Conditions

Unlabeled or mislabeled tubes will be rejected. Rejection of specimens for reasons other than unlabeled/mislabeled will be done by Mercy staff only.