Sign in →

Test Code FCQBAM Circulating Immune Complex, C1q Binding

Additional Codes

 Mayo Test ID

FCQBA

EPIC Test ID

LAB2330

Reporting Name

CIC, C1q Binding

Performing Laboratory

ARUP Laboratories

Specimen Type

Serum


Specimen Required


Collection Container/Tube: Red top or serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL serum

Collection Instructions:

1. Allow complete clotting of red blood cells (up to 1 hour).

2. Within 30 minutes after clotting is complete, centrifuge and aliquot serum into a plastic vial.

3. Freeze immediately.

4. Ship frozen.

Note: Critical frozen. Separate specimens must be submitted when multiple tests are ordered.


Specimen Minimum Volume

Serum: 0.3 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen 14 days

Reference Values

Less than or equal to 3.9 ug Eq/mL

Day(s) Performed

Saturday, Monday, and Thursday

CPT Code Information

86332

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FCQBA CIC, C1q Binding 27831-7

 

Result ID Test Result Name Result LOINC Value
Z2636 CIC, C1q Binding 27831-7

Report Available

4 to 15 days

Reject Due To

Gross hemolysis: Reject
Thawing: Cold reject; Warm reject
Non-frozen specimen Reject

Method Name

Semi-Quantitative Enzyme-Linked Immunosorbent Assay

Useful For

Detecting circulating immune complexes