Test Code SFOLGM Oligoclonal Banding, Serum and Spinal Fluid
Additional Codes
MAYO Test ID |
OLIG |
EPIC Test ID |
LAB740 |
Reporting Name
Oligoclonal BandingUseful For
Diagnosis of multiple sclerosis; especially useful in patients with equivocal clinical presentation and radiological findings
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
OLIGS | Serum Bands | No | Yes |
OLIGC | CSF Bands | No | Yes |
Method Name
Isoelectric Focusing (IEF) with IgG Immunoblot Detection
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
CSFSerum
Specimen Required
Both serum and spinal fluid are required. Spinal fluid must be obtained within 7 days of serum collection.
Specimen Type: Serum
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.
2. Label specimen as serum.
Specimen Type: Spinal fluid
Container/Tube: Sterile vial
Specimen Volume: 0.5 mL
Collection Instructions: Label specimen as spinal fluid.
Specimen Minimum Volume
Serum, Spinal Fluid: 0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
CSF | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen | 14 days | ||
Serum | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen | 14 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
CSF Oligoclonal Bands Interpretation: <2 bands
Day(s) Performed
Monday through Friday
CPT Code Information
83916 x 2
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
OLIG | Oligoclonal Banding | 100757-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
8017 | CSF Bands | 49852-7 |
2783 | Serum Bands | 100755-8 |
23611 | CSF Olig Bands Interpretation | 100756-6 |