Test Code BASICF Basic Metabolic Panel - Fasting
Additional Codes
Test ID |
BASICF |
EPIC Test ID |
LAB0015 |
Performing Laboratory
St. Luke's Hospital Cedar Rapids
Specimen Requirements
Container/Tube:
Preferred: Mint Green-top (lithium heparin) tube-Hemolyzed specimen or sodium heparin tube is not acceptable.
Acceptable: Green-top tube, gold-top serum gel tube or plain, red-top tube
Specimen: 0.2 mL of lithium heparin plasma or serum
Stability: 3 days at 4°C
Collection Instructions: For glucose testing a fasting specimen is preferred. Tube should be kept capped as much as possible to avoid decreasing the CO2 concentration. Immediate testing is preferred.
Note: Elevated platelets can cause a falsely elevated serum potassium level because of the release of potassium during clotting process. Specimens from patients with elevated platelet counts must be drawn in a heparinized plasma tube.
Reference Values
See individual test listings.
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
80048
Panel
Profile Information: | |
Blood Urea Nitrogen (BUN) | Creatinine |
Calcium | Glucose |
Carbon Dioxide (CO2) | Potassium |
Chloride | Sodium |
Report Available
STAT within 1 hour of receipt
Routine within 2 hours of receipt